Operating performance Pumping in Central Pivot using Inverter Frequency

Adenilsom dos Santos Lima, João Luiz Zocoler, Sidnei Osmar Jadoski, Marcio Furlan Maggi, Regiane Rodrigues do Amarante

Abstract


The study aimed to evaluate the variation of the following parameters: rotation of the motor pump set, power developed by the electric motor and reduction of energy consumption in pumping set of the center pivot irrigation system, operating in two programming levels the frequency inverter and three positions of operation. The experimental design was completely randomized, being made three replications in each tested position . It was applied to analysis of variance Followed by Tukey ‘s test. Two operation conditions were tested: Test 1 with constant pressure in the output of motor pump set, and Test 2 with variable rotation in accordance with the need of pressure of system. For each condition of operation were tested three positions of lines of collecting: incline of 3.45%, level and slope with 11.78%. The results showed that the lateral line position significantly influenced the rotation of the motor pump set, consequently, the power developed by the engine and the power consumption. Mainly in the test 2 condition, showing the frequency inverter operating mode.

Keywords


Rotation, consumption , power , irrigation.

References


ALVES, J.A. et al.: Verificações das relações de Rateaux pelo emprego de um inversor de freqüência. In: Revista Brasileira de Engenharia Agrícola e Ambiental, v.6, n.3, p.523-525, 2002 Campina Grande, PB

AQUINO, R.R.R.; et al. Eficientização energética em métodos de controle de vazão. In: VIII Conferência Internacional de Aplicações Industriais. Poços de Caldas, 2008.

ARAÚJO, J.A.B. Aplicação de inversor de freqüência para economia de energia elétrica, em sistema de irrigação por aspersão. Botucatu, 2003. 62p. Tese (Doutorado em Agronomia - Irrigação e Drenagem) – Faculdade de Ciências Agronômicas, Universidade Estadual Paulista. Botucatu, SP, 2003.

CAMPANA, S. Racionalização do uso de energia elétrica em sistemas de irrigação tipos pivô central e aspersão convencional. 2000. 108p. Dissertação (Mestrado em Engenharia Agrícola)-Universidade Federal de Viçosa, Viçosa

CAMPANA, S., OLIVEIRA FILHO, D., SOARES, A.A. et al. Inversores de frequência: uma alternativa para racionalização do uso da energia elétrica em sistemas de irrigação pivô central.. In: ENCONTRO DE ENERGIA NO MEIO RURAL, 3., 2000, Campinas.Proceedings online... Available from: . Acess on: 07 Apr. 2016.

CAPELLI, A. Inversores de freqüência. Revista Mecatrônica Atual, São Paulo, n. 2, p. 7-15, fev. 2002

CARVALHO, J.A. Hidráulica básica. In: MIRANDA, J.H. de; PIRE, R.C. de M. Irrigação. Piracicaba: FUNEP, 2003. cap. 15, v.2, p. 1-106.

CARVALHO, J.A.; et al. Utilização do inversor de freqüência em sistemas de irrigação para controle de vazão. In: Revista Brasileira de Engenharia Agrícola e Ambiental, v.4, n.1, p.51-56, 2000. Campina Grande, PB.

FERNANDES, R.F.: et al. Sistema de Acionamento Elétrico para Motor de Indução Trifásico (MIT) Aplicado no Bombeamento de Água. In: Anais do VII Salão Internacional de Ensino, Pesquisa e Extensão – Universidade Federal do Pampa. v.7, n. 2 (2015).

JIMÉNEZ-BELLO, M. Á., ALZAMORA, F. M., CASTEL, J. R., INTRIGLIOLO, D. S. Validation of a methodology for grouping intakes of pressurized irrigation networks into sectors to minimize energy consumption. Agricultural Water Management, n.102, p.46-53,2011.

MEDEIROS, A. M. de M. Otimização de sistema de irrigação por aspersão pivô central. 2010. 131 f. Tese (Doutorado em Agronomia: Solo e Água) - Escola de Agronomia e Engenharia de Alimentos, Universidade Federal de Goiás, Goiânia, 2010

Moraes, M. J., Oliveira Filho, D., Mantovani, E. C., Monteiro, P. M. B., Mendes, A. L. C., Damião, J. C. Automação em sistema de irrigação tipo pivô central para economia de energia elétrica. Engenharia Agrícola, v. 34, n.6, p. 1075-1088, 2014.

SCHMIDLIN Jr., C. R. Operação do conjunto bomba centrífuga, motor de indução trifásico e conversor de freqüência visando a eficiência no uso da energia elétrica. Fortaleza, 2006. Dissertação (Mestrado em Engenharia Elétrica) – Universidade Federal do Ceará. Fortaleza, CE, 2006.

WEG. Guia de aplicação de energia. Jaraguá do Sul: WEG, 2002. 238p.

WEG. Manual do inversor de freqüência CFW-09. Jaraguá do Sul: WEG, 2006. 361p.




DOI: https://doi.org/10.5935/PAeT.V8.N2.06